The Yaskawa J1000 Inverter is a compact variable speed inverter drive providing efficient, high performance features in a compact package. All of Yaskawa’s J1000 range of inverters are designed with simple “plug and play” installation in mind, offering user friendly parameter programming while still being highly adaptable for a variety of applications. The JCBA line is designed to run on a 200 V, single phase (1ph) line.
More information about Yaskawa J1000 Inverters can be found here: J1000 Brochure
Goodwin Electronics also offers installation and panel design options for J1000 inverters, for more information on this service please feel free to contact us here: Contact Us
Model Number | CIMR-JCBA0006BAA | |
Voltage Class | 200 V | |
Output | Motor Output (kW) Normal Duty | 1.1 |
Motor Output (kW) Heavy Duty | 0.75 | |
Rated Output (A) Normal Duty | 6.0 | |
Rated Output (A) Heavy Duty | 5.0 | |
Rated Output Power (kVA) Normal Duty | 2.3 | |
Rated Output Power (kVA) Heavy Duty | 1.9 | |
Max. Output Voltage | Three-phase 200 to 240 V (relative to input voltage) | |
Max. Output Frequency | 400 Hz | |
Input | Rated Input Voltage | Single Phase 200 to 240 V +10% / -15% |
Rated Input Frequency | 50 / 60 Hz, ±5% |
Control Methods | V/F Control |
Frequency Control Range | 0.01 to 400 Hz |
Frequency Accuracy | Digital Input: ±0.01% of the Max. Output Freq. (-10°c to +50°c) |
Analog Input: ±0.05% of the Max. Output Freq. (25°c ±10°c) | |
Frequency Setting Resolution | Digital Input: 0.01 Hz |
Analog Input: 1/1000 of Max. Freq. | |
Starting Torque | 150% / 3 Hz |
Speed Control Range | 1:20 |
Motor Protection | Motor overheat protection based on output current |
Momentary Overcurrent Protection | Drive stops when output current exceeds 200% of Heavy Duty Rating |
Overload Protection | 120% for 60 sec. at normal duty, 150% for 60 sec. at heavy duty |
Overvoltage Protection | Stops when DC bus exceeds approx. 410 V |
Undervoltage Protection | Stops when DC bus Voltage falls below approx. 160 V |
Drive Overheat Protection | Protected by thermistor |
Areas of Use | Indoors |
Ambient Temperature | -10 to +50°C (IP20 open chassis) |
Humidity | 95 RH% or less (no condensation) |
Storage Temperature | -20 to +60°C (short term temperature during transportation) |
Altitude | Max. 1000m (output derating of 1% per 100m above 1000m, max. 3000m) |
Shock | 10 to 20 Hz (9.8 m/s²) max., 20 to 55 Hz (5.9m/s²) max. |