Description
The J1000 series is in the process of being discontinued. We advise customers to upgrade to the GA500 series equivalent. Please contact our sales team for more information on transitioning from the J1000 to GA500.
The Yaskawa J1000 Inverter is a compact variable speed inverter drive providing efficient, high performance features in a compact package. All of Yaskawa’s J1000 range of inverters are designed with simple “plug and play” installation in mind, offering user friendly parameter programming while still being highly adaptable for a variety of applications. The JCBA line is designed to run on a 200 V, single phase (1ph) line.
For more information about Yaskawa J1000 Inverters can be found here: J1000 Brochure
Goodwin Electronics also offers installation and panel design options for J1000 inverters, for more information on this service please feel free to contact us here: Contact Us
Model Number | CIMR-JCBA0002BAA | |
Voltage Class | 200 V | |
Output | Motor Output (kW) Normal Duty | 0.4 |
Motor Output (kW) Heavy Duty | 0.2 | |
Rated Output (A) Normal Duty | 1.9 | |
Rated Output (A) Heavy Duty | 1.6 | |
Rated Output Power (kVA) Normal Duty | 0.7 | |
Rated Output Power (kVA) Heavy Duty | 0.6 | |
Max. Output Voltage | Three-phase 200 to 240 V (relative to input voltage) | |
Max. Output Frequency | 400 Hz | |
Input | Rated Input Voltage | Single Phase 200 to 240 V +10% / -15% |
Rated Input Frequency | 50 / 60 Hz, ±5% |
Control Methods | V/F Control |
Frequency Control Range | 0.01 to 400 Hz |
Frequency Accuracy | Digital Input: ±0.01% of the Max. Output Freq. (-10°c to +50°c) |
Analog Input: ±0.05% of the Max. Output Freq. (25°c ±10°c) | |
Frequency Setting Resolution | Digital Input: 0.01 Hz |
Analog Input: 1/1000 of Max. Freq. | |
Starting Torque | 150% / 3 Hz |
Speed Control Range | 1:20 |
Motor Protection | Motor overheat protection based on output current |
Momentary Overcurrent Protection | Drive stops when output current exceeds 200% of Heavy Duty Rating |
Overload Protection | 120% for 60 sec. at normal duty, 150% for 60 sec. at heavy duty |
Overvoltage Protection | Stops when DC bus exceeds approx. 410 V |
Undervoltage Protection | Stops when DC bus Voltage falls below approx. 160 V |
Drive Overheat Protection | Protected by thermistor |
Areas of Use | Indoors |
Ambient Temperature | -10 to +50°C (IP20 open chassis) |
Humidity | 95 RH% or less (no condensation) |
Storage Temperature | -20 to +60°c (short term temperature during transportation) |
Altitude | Max. 1000m (output derating of 1% per 100m above 1000m, max. 3000m) |
Shock | 10 to 20 Hz (9.8 m/s²) max., 20 to 55 Hz (5.9m/s²) max. |